We are a leading Manufacturer of brass sheet cutting components and lightning emp protector from Jamnagar, India.

Brass Sheet Cutting Components

Brass Sheet Cutting Components
  • Brass Sheet Cutting Components
  • Brass Sheet Cutting Components
  • Brass Sheet Cutting Components
Get Best Quote
Approx. Price: Rs 5 / PieceGet Latest Price
Product Brochure

Product Details:

Usage/ApplicationsCustomized Components
Usage/ApplicationIndustrial
Materialbrass
TypeAs per Requirement
Country of OriginMade in India

We have emerged as a leading organization, involved in offering our clients high quality Brass Components. Owing to their high strength and minimum maintenance, the offered components are highly demanded among our precious clients. In adherence to the set industry standards, the provided components are well-manufactured by our highly experienced professionals. Further, our valuable clients can avail these components from us at industry leading prices.
Request
Callback
Yes! I am Interested

Lightning Emp Protector

Lightning Emp Protector
  • Lightning Emp Protector
  • Lightning Emp Protector
  • Lightning Emp Protector
Get Best Quote
Approx. Price: Rs 120 / PieceGet Latest Price
Product Brochure

Product Details:

Current Rating5kA
Rated Voltage11kV
Country of OriginMade in India
Packaging TypeBox
ColorWhite

A 5kA Lightning Protector (or Lightning Arrester) is a device designed to protect electrical systems and equipment from the destructive effects of lightning strikes. It helps by safely diverting the high voltage and current from a lightning strike to the ground, preventing damage to sensitive equipment and electrical installations. These devices are commonly used in power distribution systems, telecommunications, industrial facilities, and other infrastructure.

Below is a detailed specification for a 5kA Lightning Protector:

1. Nominal Discharge Current:
  • 5 kA: The lightning protector is designed to handle a nominal discharge current of 5,000 Amps (5 kA), which refers to the typical lightning current the device can safely divert without causing damage.
  • The value 5 kA indicates the protector’s capacity to safely dissipate the energy from a lightning strike, reducing the risk of damage to electrical equipment.
2. Maximum Discharge Current (I_max):
  • I_max (Maximum Discharge Current) indicates the peak current that the protector can safely handle during a direct lightning strike or surge event. Common values for I_max in lightning arresters are:
    • 10 kA, 20 kA, 40 kA, depending on the specific model and application.
    • For a 5 kA Lightning Protector, the I_max could be between 10 kA to 20 kA, allowing for protection from multiple or stronger lightning strikes.
3. Voltage Protection Level (UP):
  • UP (Voltage Protection Level) is the maximum voltage that appears across the protector’s terminals when it diverts a lightning strike. The protector should limit this voltage to a safe level for the equipment.
  • The voltage protection level (UP) typically ranges from 600V to 1.5kV for a 5 kA lightning protector. Lower values indicate better protection, as they prevent overvoltage conditions that could damage equipment.
4. Type of Protection:
  • Class I / Type 1 Protector: A 5 kA Lightning Protector would typically fall under Class I or Type 1, meaning it is designed to protect against direct lightning strikes. These protectors are installed at the main power distribution board or building entry point to intercept lightning strikes before they enter the electrical system.
  • These protectors generally include spark gaps, air terminals, and metal oxide varistors (MOVs) to divert the lightning current to the ground.
5. Response Time:
  • The response time is the time it takes for the lightning protector to react to a surge or lightning strike and start diverting the current. For effective protection, the response time should be as fast as possible.
  • Typical response time for these devices is in the range of nanoseconds to microseconds, ensuring the device reacts quickly to lightning strikes.
6. Grounding / Earthing System:
  • Lightning protectors work by diverting the lightning energy into the ground through a properly installed earthing system. The protector itself will typically have a ground terminal for connecting to the earth electrode.
  • The quality of the earth connection is critical for the effectiveness of the lightning protector. A low-resistance ground connection should be maintained.
7. Surge Capacity:
  • Surge Capacity indicates how much transient surge energy the protector can absorb without failing. For a 5 kA Lightning Protector, the surge capacity typically ranges from 10 kA to 50 kA, depending on the model.
  • Protectors are often rated for handling multiple surge events over their lifetime.